Disinfection testing instruments, tableware cleanliness testers, microbial bacteria testers, rapid microbial testing instruments, and total bacterial count rapid testers.

Short Description:

This device is a newly upgraded product with a large touchscreen display replacing traditional buttons. Operation utilizes a biochemical reaction method to detect ATP content. The ATP fluorescence detector is based on the firefly bioluminescence principle, using a "luciferase-luciferin system" to rapidly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse cell membranes, releasing intracellular ATP. This ATP reacts with a specific enzyme in the reagent, producing light, which is then detected by a fluorometer. The number of microorganisms is directly proportional to the light emission value. Since all living cells contain a constant amount of ATP, the ATP content clearly indicates the amount of microorganisms and other biological residues in the sample, used to assess hygiene conditions.


  • Model:
  • Category:
  • Item No:
  • Type:

Product Details

Graphic introduction


Product Introduction: This newly upgraded device features a large touchscreen display, replacing traditional buttons. Operation utilizes a biochemical reaction method to detect ATP content. The ATP fluorescence detector is based on the firefly bioluminescence principle, using a "luciferase-luciferin system" to rapidly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse cell membranes, releasing intracellular ATP. This ATP reacts with a specific enzyme in the reagent, producing light. The luminescence value is then detected by a fluorometer. The number of microorganisms is directly proportional to the luminescence value. Since all living cells contain a constant amount of ATP, the ATP content clearly indicates the amount of microorganisms and other biological residues in the sample, used to assess hygiene conditions.

 

Instrument Applications: The ATP fluorescence detector is widely used in various industries, including bacterial and microbial detection, pharmaceuticals and healthcare, food safety, market enforcement, surface cleanliness testing, medical and epidemic prevention, water quality and administration, production line hygiene, industrial water treatment, environmental monitoring, customs and entry-exit quarantine, and other law enforcement departments.

 

Instrument Features:

Practicality – Upper and lower limits can be set according to environmental monitoring needs, enabling rapid data assessment and early warning, and rapid screening of surface cleanliness.

 

High sensitivity – Detection accuracy 1×10⁻¹⁵ ~ 1×10⁻¹⁸ mol ATP.

Fast speed – Conventional culture methods take 18-24 hours or more, while ATP detection only takes a few seconds.

Feasibility – There is a clear correlation between the number of microorganisms and the ATP content within them. By detecting the ATP content, the number of microorganisms in the reaction can be indirectly determined.

Operability – Traditional culture methods require laboratory operation by trained technicians; however, the rapid ATP cleanliness detection method is very simple to operate, requiring only simple training for general staff to perform on-site.

 

Main Parameters:

 

1. Display: 3.5-inch high-precision graphic touchscreen

 

2. Processor: 32-bit high-speed data processing chip

 

3. Detection Accuracy: 1×10⁻¹⁵ ~ 1×10⁻¹⁸ mol ATP

 

4. Detection Range: 0~999,999 RLUs

 

5. Detection Interference: ±5% or ±5 RLUs

 

6. ATP Recovery Rate: 90%~110%

 

7. Detection Time: 15 s

 

8. Detection Mode: RLU

 

9. Optional upper and lower limits

 

10. Automatic pass/fail judgment

 

11. Built-in self-calibrating light source

 

12. 30-second self-test upon startup

 

13. Operating Temperature Range: 5~40℃

 

14. Operating Humidity Range: 20%~85%

 

15. Equipped with a miniUSB interface for uploading results to a PC

 

16. Equipped with a dedicated software driver USB flash drive instead of a traditional CD.

 

17. Instrument Dimensions (W×H×D): 188 mm × 77 mm × 37 mm

 

18. 3.7 V 3000 mAh Lithium Battery

 

19. Standby Time (20℃): 6 months

 

Included Configuration: ATP Fluorescence Detector (Handheld) Main Unit, Aluminum Alloy Carrying Case, Driver USB Flash Drive, PC Data Cable, Data Analysis Software, Chinese User Manual




Get a Free Quote


Write your message here and send it to us

Get a Free Quote